PRODUCTS

Cathodic Protection Smart Test Station

3.2.jpg
video
product name

Cathodic Protection Smart Test Station

Model: AKZNCS-1

Power:

Energy:

Description: Cathodic protection samrt test station

Products Description

As the data sensing terminal of a cathodic protection system, the smart test station uses continuous and accurate potential acquisition capabilities to advance pipeline protection from occasional sampling to an entirely new dimension of all-weather digital monitoring.

The smart test station independently developed by Shandong AOKE Anticorrosion Engineering Co., Ltd. integrates multi-parameter acquisition — including ON potential, OFF potential, natural potential, AC interference voltage, AC/DC stray current, sacrificial anode output parameters and ambient temperature and humidity — building a complete perception of the pipeline protection status. Sampling errors are precisely controlled at the millivolt level, current resolution reaches the microampere level, and the channel input impedance is as high as over 20 megohms, locking in data quality at the measurement source. When the protective potential leaves the preset window, an alarm is triggered immediately, and the management end obtains the abnormal location at the first moment, flipping the old logic of passive handling into the precise response of proactive intervention.

The harsher the field conditions, the more they confirm the product's protective capability. In strong AC interference environments, the equipment maintains stable data without distortion; the 20kA-class lightning tolerance ensures continuous operation of field stations. The ultra-low power consumption design reduces the standby current to the microampere level, and combined with a large-capacity lithium battery, the equipment can operate reliably for more than five years at normal acquisition frequencies, greatly reducing routine maintenance frequency and labor costs.

In terms of communication, GPRS, 4G and fiber-optic modes flexibly adapt to different scenarios, and the remote control platform supports dynamic adjustment of sampling strategies and interruption cycles, achieving a seamless closed loop from platform to site. Whether for newly built oil and gas trunk lines or urban gas pipeline networks, it can weave a highly reliable, fully covered digital protection network.

From accurate sensing to ultra-low power consumption, from robust protection to full controllability, the smart test station uses hard-core technology to build a reliable foundation for long-term safe operation of pipelines.

The technical parameters and applicable standards of the smart test station are as follows:

1. Main Performance

The smart test station can realize automatic acquisition and data processing of cathodic protection potentials, and can monitor parameters such as cathodic protection ON potential, OFF potential, natural potential, AC interference voltage, AC stray current, DC current density, sacrificial anode open-circuit potential, sacrificial anode output current, temperature and humidity. When abnormal cathodic protection potentials are detected, it automatically alarms, making it convenient for management personnel to discover pipeline problems in time and handle them on site, greatly improving the level of cathodic protection management.

The application of the smart test station has changed the original manual data acquisition, recording and control methods, completely solving the traditional problems of running to the site, low efficiency and missed protection, and fundamentally realizing the transition from manual to intelligent.

2. Advantages

True anti-interference, lightning protection and ultra-low power consumption:

Field practice blocks all interference sources, and real-time data is accurate and error-free;

Withstands more than 16 consecutive lightning strikes in a 20kA lightning environment;

A large-capacity lithium battery can be used for more than 5 years after one installation; standby current 6μA (15-20μA for similar products); operating current: 150mA (200-400mA for similar products).

3. Scope of Application

Mainly applied to various newly built oil and gas transmission pipelines and urban gas pipeline projects.

4. Technical Parameters

No.

Parameter

Technical Indicator

1

ON potential acquisition

Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV; resolution 1%, accuracy 1%

2

OFF potential acquisition

Sampling range: DC±5V; sampling error: ≤±1mV; resolution 1%, accuracy 1%

3

Natural potential acquisition

Sampling range: DC±5V; sampling error: ≤±1mV; resolution 1%, accuracy 1%

4

AC interference voltage acquisition

Sampling range: 0V~3V, 0V~100V; sampling error: ≤0.1V

5

AC current acquisition

Sampling range: 0~100mA (current density measured with a 1m² coupon); sampling error: ≤1%; resolution: 1μA

6

DC current acquisition

Sampling range: ±100mA (current density measured with a 1m² coupon); sampling error: ≤1%; resolution: 1μA

7

Sacrificial anode open-circuit potential

Sampling range: DC±5V; sampling error: ≤±1mV; resolution 1%, accuracy 1%

8

Sacrificial anode output current

Sampling range: 200mA; sampling error: ≤1%; resolution: 1μA

9

Input impedance

≥20MΩ

10

Current flowing through the reference electrode

≤3μA

11

Communication method

GPRS communication, 4G communication or fiber-optic communication

12

OFF potential coupon interruption time

3~99999ms

13

Working modes

Daily acquisition, hourly acquisition, minute-based acquisition and continuous intensive acquisition

14

AC interference resistance

>30V

15

Remote control

Remote control supported. The sampling time, continuous sampling time, sampling frequency, OFF potential on/off time, acquisition unit online time, GPS working time and other working parameters of the smart potential acquisition unit can be adjusted through the supporting system software

16

Power supply

Disposable large-capacity lithium battery with capacity ≥30Ah; can be used for 5-8 years with one acquisition per day; rechargeable batteries or solar cells may also be used

17

Acquisition unit power consumption

Standby mode current ≤8μA; average operating current ≤150mA

18

Equipment clock

The equipment can perform time correction through satellite time synchronization or server time synchronization (the original text is incomplete here; based on the context, it is inferred to relate to clock error)

5. Applicable Standards

Reference standard: GB/T 21448-2017 Technical Specification for Cathodic Protection of Buried Steel Pipelines


Send Inquiry