Products Description
If the solid-state decoupler solves the question of "what to discharge", the smart drainage device goes one step further — it must not only discharge, but also sense, judge, adjust and compensate, forming a complete closed-loop control system.
The essential difference between the smart drainage device and traditional drainage equipment lies in proactiveness. Traditional drainage devices are passive components — they conduct when interference comes and recover when the interference disappears, with no judgment or selection throughout the process. The smart drainage device has a built-in microprocessor and sampling circuits that monitor the trend of pipe-to-soil potential changes in real time, analyze the source and intensity of stray current, and automatically match the optimal drainage strategy. More importantly, the smart drainage device can output protective current in reverse when the pipeline's cathodic protection is insufficient, functioning like a miniature potentiostat — a capability completely absent in traditional drainage equipment.
The AOKE smart drainage device integrates three core functional modules. AC drainage module: when the AC voltage induced on the pipeline is detected to exceed the safety threshold, the internal resistance is automatically reduced to guide the AC stray current into the earth through the drainage groundbed. DC drainage and potential compensation module: in the face of DC stray current, the system intelligently processes it in stages according to the pipe-to-soil potential — when the potential is higher than the protection range, drainage is activated to discharge the excess current; when the potential is lower than the protection requirement, the built-in miniature potentiostat automatically starts and supplies protective current to the pipeline. Remote communication module: through 4G/5G networks, operating data such as drainage current, pipe-to-soil potential and equipment temperature are uploaded to the management platform in real time.
In terms of detection accuracy, the AOKE smart drainage device uses high-precision sampling circuits, with pipe-to-soil potential detection errors controlled within ±1mV. The sampling ranges for AC/DC drainage current are both 0-50A, with a sampling error of ≤0.1A. The insulation resistance of the equipment enclosure is >10MΩ, and it can withstand a 1500V dielectric strength test. The whole unit adopts an IP68 protection rating and operates stably in a wide temperature range from -35℃ to +65℃. The internal circuit boards are treated with moisture-proof, salt-spray-proof and anti-bacterial measures to meet the long-term use requirements of buried and coastal harsh environments.
In practical engineering, the smart drainage device is often deployed in coordination with smart test stations. The smart test station is responsible for continuous monitoring of the pipe-to-soil potential and data upload, while the smart drainage device dynamically adjusts the drainage strategy based on the monitoring results. The two work together to form a complete closed loop of "monitoring-analysis-drainage-assessment".
The technical parameters and applicable standards of the smart integrated drainage device are as follows:
1. Technical Parameters
No. | Parameter | Technical Indicator |
1 | Operating ambient temperature | -35℃~+65℃ |
2 | Enclosure insulation resistance | >10MΩ |
3 | Dielectric strength | Can withstand a 1500V test voltage (RMS) for one minute without breakdown and flashover |
4 | Lightning protection | Meets the Level 4 lightning protection requirements of GB/T 3482 |
5 | Coupler AC drainage current (high current) | Sampling range: 0-10A, 0-50A (AC50Hz); sampling error: ≤0.1A |
6 | Coupler DC drainage current (high current) | Sampling range: 0-10A, 0-50A; sampling error: ≤0.1A |
7 | Pipeline AC induced voltage after drainage | Sampling range: 0V~30V, 0V~100V; sampling error: ≤0.1V |
8 | Pipeline AC induced voltage with drainage disconnected | Sampling range: 0V~30V, 0V~100V; sampling error: ≤0.1V |
9 | Drainage groundbed potential | Sampling range: DC±5V; sampling error: ≤±1mV |
10 | Drainage groundbed AC voltage | Sampling range: 0V~30V, 0V~100V; sampling error: ≤0.1V |
11 | Pipeline ON potential | Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV |
12 | Pipeline ON potential with drainage disconnected | Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV |
13 | Smart coupler differential voltage | Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV |
14 | Smart coupler impedance | Sampling range: 0-200mΩ; sampling error: ±1mΩ |
15 | Smart coupler operating temperature | Sampling range: -40℃~+150℃; sampling error: ±0.5℃ |
16 | Pipeline OFF potential | Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV; resolution 1%, accuracy 1% |
17 | Pipeline natural potential | Sampling range: DC±5V, DC±100V; sampling error: ≤±1mV; resolution 1%, accuracy 1% |
18 | AC current acquisition | Sampling range: 0~300mA (current density measured with a 1cm² coupon); sampling error: ≤1%; resolution: 1μA |
19 | Coupon DC current acquisition | Sampling range: ±300mA (current density measured with a 1cm² coupon); sampling error: ≤1%; resolution: 1μA |
20 | Channel input impedance | ≥10MΩ |
21 | Current flowing through the reference electrode | ≤3μA |
22 | Installation method | Test station bracket installation, buried protection box installation, and dedicated explosion-proof box installation for explosion-proof environments |
23 | Communication method | GPRS communication, 4G/5G communication |
24 | Acquisition working modes | Daily acquisition, hourly acquisition, minute-based acquisition and continuous intensive acquisition and other modes |
25 | Power supply | Disposable large-capacity lithium battery with a battery voltage of 7.2V and capacity ≥28A·h |
26 | Smart coupler power consumption | Standby mode current ≤8μA; average operating current ≤150mA |
27 | Equipment clock | Time correction through satellite time synchronization or server time synchronization; clock error less than 0.5 seconds per day |
28 | Wireless remote upgrade | The embedded control program inside the acquisition unit can be upgraded remotely through wireless transmission |
29 | Circuit board protection | Moisture-proof, salt-spray-proof and anti-bacterial measures adopted to meet the requirements of buried and harsh environment use |
30 | Design features | Highly integrated, compact design, compatible with 95% of the drainage test stations on the market |
31 | Equipment identification | The enclosure is marked with the motherboard serial number and standard IoT SIM card number label for convenient subsequent payment |
32 | Serial port output | After each acquisition, the data is first output through the serial port, then the network is enabled for data upload |
33 | Communication protocol | TCP/IP or MQTT communication, remotely controlled and adjusted according to the requirements of the business department |
34 | Communication anomaly protection | Has data storage capability; when communication is abnormal, more than 1 year of operating data can be stored, and data is automatically uploaded after communication is restored |
2. Applicable Standards
Reference standard: GB/T 18802-2021 Low-Voltage Surge Protective Devices (SPD)