Products Description
The Smart CP Data Acquisition serves as the core component of the data sensing link for the cathodic protection (CP) system. Capable of continuous and accurate potential capture, it elevates pipeline protection from occasional spot‑checking to a brand‑new dimension of all‑weather digital monitoring.
Developed independently by Shandong Aoke Anti‑Corrosion Engineering Co., Ltd., the Smart CP Data Acquisition (Model: AK‑ZNCS‑01) integrates multi‑parameter acquisition including on‑potential, instant‑off potential, native potential, AC interference voltage, AC and DC stray current, output parameters of sacrificial anode, as well as ambient temperature and humidity, building complete perception for pipeline protection status. This product has passed strict inspections conducted by the Electronic Instrument Laboratory of Tianjin Institute of Metrological Supervision and Testing, in accordance with national standards including GB/T 2423.2‑2008, GB/T 2423.1‑2008, GB/T 4208‑2017 and GB 4943.1‑2011. All inspected items meet the requirements of the Product Technical Specification, and a test report bearing CNAS and ILAC‑MRA international mutual‑recognition marks has been issued.
Sampling error is controlled at the millivolt level (measured error ≤0.06% under the ±5 V range). Current resolution reaches the microampere level, and channel input impedance is higher than 20 MΩ, guaranteeing data quality at the source of measurement. Alarms are triggered immediately once the protection potential deviates from the preset window, enabling the management terminal to obtain anomaly location in real time. This transforms the old logic of passive disposal into precise response with proactive intervention.
Harsh field conditions further demonstrate the equipment’s robust protection performance. It maintains stable and undistorted data under severe AC interference environments, and features 20 kA lightning withstand capacity to ensure continuous operation of field outdoor sites. The product has successfully passed environmental tests: 16‑hour continuous operation at 75 °C high temperature and 16‑hour continuous operation at ‑35 °C low‑temperature. It also complies with IP6X dust‑proof and IPX8 water‑proof ratings (1000 mm underwater for 40 minutes). Adopting ultra‑low‑power design, the standby current is measured below 8 μA. When paired with large‑capacity lithium batteries (≥30 Ah), it can operate stably for more than five years under normal sampling frequency, significantly reducing routine maintenance frequency and labour costs.
For communication, multiple modes including GPRS, 4G, LoRa and optical fibre are flexibly adapted to diverse scenarios. The remote control platform supports dynamic adjustment of sampling strategy and on‑off cycle, achieving a seamless closed‑loop from platform to field sites. Whether for newly‑built oil & gas trunk pipelines or urban gas pipeline networks, it helps build a highly‑reliable and full‑coverage digital protection network.
With advantages ranging from precise sensing and ultra‑low power consumption to robust environmental resistance and full‑process controllability, the Smart CP Data Acquisition provides a solid underlying foundation for long‑term safe pipeline operation.
Technical Parameters and Applicable Standards of the Smart CP Data Acquisition
1. Main Performance
The Smart CP Data Acquisition can automatically collect and process cathodic protection potentials. It monitors parameters such as cathodic protection on‑potential, instant‑off potential, native potential, AC interference voltage, AC stray current, DC current density, open‑circuit potential of sacrificial anode, output current of sacrificial anode, temperature and humidity. Automatic alarms are activated when abnormal cathodic protection potentials are detected, helping managers identify pipeline defects promptly and conduct on‑site troubleshooting, and greatly improving cathodic protection management.
Its application changes traditional manual data collection, recording and regulation modes. It fundamentally eliminates drawbacks such as frequent site visits, low efficiency and unprotected sections, and realises the transformation from manual operation to intelligent management.
2. Advantages
True anti‑interference, lightning‑resistance and ultra‑low power consumption:
Blocks interference sources under field conditions to guarantee accurate real‑time data;
Withstands more than 16 consecutive lightning strikes under 20 kA lightning conditions;
A single installation of large‑capacity lithium battery supports service life over 5 years; standby current ≤8 μA (verified by test laboratory measurement); average operating current ≤150 mA (verified by test laboratory measurement).
3. Scope of Application
Mainly applied to various newly‑built oil transmission pipelines, gas transmission pipelines and urban gas pipeline projects, acting as the core data‑acquisition unit for smart test stations.
Technical Parameters
(All parameters are measured conclusions from the CNAS‑accredited laboratory test report (Report No. TDYY‑220861‑WT), all items are qualified.)
表格
| No. | Parameter Item | Technical Index (Including Measured Results) |
|---|---|---|
| 1 | On‑potential Acquisition | Sampling range: DC ±5 V, DC ±100 V; sampling error ≤0.1% for ±5 V range (measured: 0.06%), sampling error ≤1% for ±100 V range (measured: 0.11%) |
| 2 | Instant‑off Potential Acquisition | Sampling range: DC ±5 V, DC ±100 V; sampling error ≤0.1% for ±5 V range (measured: 0.02%), sampling error ≤1% for ±100 V range (measured: 0.12%) |
| 3 | Native Potential Acquisition | Sampling range: DC ±5 V, DC ±100 V; sampling error ≤0.1% for ±5 V range (measured: 0.04%), sampling error ≤1% for ±100 V range (measured: 0.09%) |
| 4 | AC Interference Voltage Acquisition | Sampling range: 0‑30 V, 0‑100 V; sampling error ≤0.1% (measured: 0.016%‑0.042%) |
| 5 | AC Current Acquisition | Sampling range: 0‑300 mA; sampling error ≤1% (measured: 0.28%‑0.33%); resolution: 1 μA |
| 6 | DC Current Acquisition | Sampling range: ±300 mA; sampling error ≤1% (measured: 0.30%‑0.40%); resolution: 1 μA |
| 7 | Sacrificial Anode Open‑circuit Potential | Sampling range: DC ±5 V; sampling error ≤0.1% (measured: 0.08%) |
| 8 | Sacrificial Anode Output Current | Sampling range: ±300 mA; sampling error ≤1% (measured: 0.25%‑0.30%); resolution: 1 μA |
| 9 | Temperature Acquisition | Sampling range: ‑40~150 ℃; sampling error ±0.5 ℃ (measured: 0.4 ℃) |
| 10 | Humidity Acquisition | Sampling range: 1‑99% RH; sampling error ±1% RH (measured: 0.6‑0.8% RH) |
| 11 | Input Impedance | ≥20 MΩ (Qualified) |
| 12 | Current through Reference Electrode | ≤3 μA (Qualified) |
| 13 | Communication Modes | GPRS, 4G, LoRa, Optical Fibre |
| 14 | On‑off Time for Instant‑off Potential Test Coupon | 3 ms ~ 9999 ms |
| 15 | Operating Modes | Daily sampling, hourly sampling, minute‑based sampling and continuous dense sampling |
| 16 | AC Interference Resistance | ≤30 V (Qualified) |
| 17 | Remote Control | Remote control supported; sampling time, continuous sampling duration, sampling frequency, on‑off time, online duration and GPS operating time are adjustable |
| 18 | Power Supply Mode | Disposable large‑capacity lithium battery (≥30 Ah); service life of 5‑8 years with one data record per day; rechargeable battery or solar power is optional |
| 19 | Power Consumption of Acquisition Instrument | Standby‑mode current ≤8 μA (measured); average operating current ≤150 mA (measured) |
| 20 | Device Clock | On‑board clock; time calibration via satellite / server; clock drift <0.5 seconds per 24 hours |
| 21 | Wireless Remote Firmware Upgrade | Remote upgrade of embedded firmware via wireless communication |
| 22 | Automatic Triggered Monitoring | Automatically increase acquisition, storage and transmission frequency when potential offset exceeds set threshold; automatically restore normal mode after interference disappears |
| 23 | Serial Port Output Support | Serial‑port output is completed prior to network upload after each sampling cycle |
| 24 | Communication Exception Protection | Can store operating data for more than 5 years; automatically re‑transmit data after communication recovery |
| 25 | Other Functions | Highly‑integrated compact design, compatible with multiple test posts; serial number of mainboard and IoT SIM card label on enclosure; TCP/IP communication supports integration with third‑party systems; standard API interface provided for compatibility with existing intelligent management systems; supports dual‑channel simultaneous measurement of AC & DC potentials; can be used as insulating joint tester and grounding potential tester for solid‑state decoupler; supports recording of ambient temperature‑humidity curves |
Applicable Standards
(Inspected by CNAS‑accredited laboratory)
GB/T 2423.2‑2008, Environmental testing for electric and electronic products — Part 2: Test methods — Test B: Dry heat
GB/T 2423.1‑2008, Environmental testing for electric and electronic products — Part 2: Test methods — Test A: Cold
GB/T 4208‑2017, Degrees of protection provided by enclosures (IP Code)
GB 4943.1‑2011, Information technology equipment — Safety — Part 1: General requirements
Reference Standard: GB/T 21448‑2017, Specification for cathodic protection of buried steel pipelines