NEWS

Company news

How is the "Protective Potential" of Cathodic Protection Determined? Where does the −0.85 V Criterion Come From

2025-03-26

Introduction

Those engaged in cathodic protection are familiar with −0.85 V as the criterion for protective potential. But where does this value originate? Why −0.85 V instead of −0.8 V or −0.9 V? Understanding the origin and applicable conditions of this standard helps correctly evaluate protection performance in fieldwork.

Theoretical Basis for Protective Potential

The determination of protective potential is based on the electrochemical behaviour of steel in soil. Based on extensive laboratory tests and accumulated field data, the industry has established that corrosion rate of steel decreases to a negligible level when its polarized potential reaches −0.85 V (vs. Copper/Copper Sulfate Reference Electrode) or more negative.

This value is not arbitrarily defined; it is derived from corrosionrate measurements of steel under different potential levels. Corrosion continues to proceed when the potential is more positive than −0.85 V; corrosion rate drops significantly once the potential goes to −0.85 V or more negative. Therefore, −0.85 V is defined as the threshold criterion for effective cathodic protection.

OffPotential is the Criterion for Judgement

It shall be emphasized that offpotential, not onpotential, shall be used to assess protection effectiveness. The onpotential includes IR drop, rendering it more negative than the true electrode potential. While it may appear to meet the criterion, it cannot reflect the actual polarization status of pipelines.

Offpotential eliminates the influence of IR drop and represents the real polarization magnitude at the pipeline surface. Effective cathodic protection can only be confirmed when the offpotential is −0.85 V or more negative. This point is frequently overlooked in practice and may lead to misjudgement of protection performance.

Applicability under Diverse Service Conditions

−0.85 V serves as a general criterion, yet adjustments shall be made for specific environments. For example, more negative protective potential may be required for soils containing sulfatereducing bacteria. Revised criteria also apply to hightemperature pipelines (operating temperature above 40 °C).

For pipelines with intact coating and moderate soil resistivity, −0.85 V is normally sufficient. Older pipelines or sections exposed to highly corrosive environments may demand more negative potential to guarantee protection effectiveness.

Risks of OverProtection

More negative potential does not equal better protection. When potential is more negative than approximately −1.2 V, overprotection may occur. Overprotection can cause cathodic disbondment of coating and may introduce hydrogen embrittlement risk. Accordingly, the objective is to maintain potential within the proper protection range, rather than pursuing an infinitely more negative value.

In operation, the setpoint of the Smart Potentiostat shall be configured to achieve adequate protection while avoiding overprotection. Continuous monitoring capability of Smart Potentiostat facilitates maintaining this balance.

Key Considerations for Potential Measurement

Protective potential measurement shall adopt qualified Reference Electrode and follow proper measurement procedures. Offpotential measurement can be implemented by utilising the onoff switching function of potentiostats or the coupon offpotential method. Periodic calibration of reference electrodes and verification of measuringinstrument accuracy are essential for reliable data.

Conclusion

The −0.85 V protectivepotential criterion results from longterm theoretical research and practical experience. Comprehending its origin and applicable conditions, and attaching importance to offpotential during measurement and assessment, enables accurate evaluation of pipeline cathodicprotection status. The management target for protective potential is stable operation within a reasonable range, instead of merely pursuing a more negative numerical reading.