Products Description
With the rapid development of modern transportation infrastructure, buried metallic pipelines are confronted with an invisible threat: stray current. In electrified railways, metro traction systems and high‑voltage transmission lines, partial electric current leaks into the earth during routine operation. These currents travel through soil and preferentially flow into buried pipelines owing to their lower resistance, and concentrate to discharge at coating defects. This generates extremely high local current density, and the corrosion rate can reach dozens of times that under natural conditions. Violent fluctuations of pipe‑to‑soil potential on monitoring screens serve as a clear indicator of stray‑current intrusion.
The Solid‑State Decoupler is engineered to mitigate this hazard. Installed between the pipeline and grounding electrode, it acts as an intelligent valve: it opens a conducting path for detrimental AC interference and transient surges, while blocking DC current required for pipeline cathodic protection. This characteristic can be summarized in eight words: block DC, pass AC; over‑voltage amplitude limiting.
Under normal operating conditions, the pipeline cathodic‑protection system applies DC current to the pipeline. The solid‑state decoupler presents high‑impedance state for DC, and leakage current is strictly limited within 1 mA. This ensures cathodic‑protection current is fully utilized for pipeline corrosion prevention without leaking to earth via the grounding electrode. When AC voltage is induced on the pipeline by adjacent high‑voltage power lines or railway traction current, the solid‑state decoupler switches to low‑impedance state within microseconds, safely discharging AC stray current to ground and restoring pipe‑to‑soil potential to the normal range. In the event of lightning surges, its response is even faster: it conducts in nanoseconds, diverting transient current up to 100 kA to earth, and automatically reverts to high‑impedance isolation after the surge subsides.
The AK‑LS5D‑50/200B Solid‑State Decoupler, independently developed by Shandong Aoke, delivers industry‑leading performance. Its DC turn‑on voltage (at 1 mA) is ‑2 V / +2 V; rated AC‑DC drainage current reaches 50 A; impulse conduction voltage ≤ 2200 V; nominal discharge current (8/20 μs waveform) In is 100 kA; maximum discharge current (8/20 μs waveform) Imax reaches 200 kA. Housed in a stainless‑steel enclosure with IP68 degree of protection, the unit operates stably over a wide temperature range of ‑45 ℃ to 60 ℃. Its internal triple‑proof construction (moisture‑proof, salt‑fog‑proof, bacteria‑proof) guarantees long‑term reliable service in buried and harsh environments. As an alternative solution, the clamping‑type drainage unit features impulse conduction voltage ≤ 620 V, nominal discharge current of 20 kA and response time ≤ 25 ns, and is suitable for working conditions with conventional protection‑grade requirements.
Technical Parameters and Applicable Standards for Solid‑State Decouplers
1. Type‑1 Solid‑State Decoupler
| Parameter Item | Technical Specification |
|---|---|
| Rated isolation voltage (leakage current ≤ 1 mA) | ‑2 V / +2 V |
| Rated lightning impulse current capacity (4/10 μs waveform) | 100 kA |
| Steady‑state AC current (under ‑2 V / +2 V condition) | ≤ 45 A |
| DC leakage current | ≤ 1 mA |
| Fault current (AC‑rms / power‑frequency / 30 cycles) | ≥ 3500 A |
| Operating temperature | ‑45 ℃ ~ 60 ℃ |
| Degree of protection | IP65 |
| Protection enclosure | Die‑cast alloy housing |
| Coating system | Zinc‑rich epoxy primer (≥ 60 μm) + epoxy micaceous iron intermediate coat (≥ 60 μm) + fluorocarbon or acrylic‑polyurethane topcoat (≥ 80 μm); total dry‑film thickness ≥ 200 μm |
2. Model AK‑LS5D‑50/200B Solid‑State Decoupler
| Parameter Item | Technical Specification |
|---|---|
| DC turn‑on voltage (at 1 mA) | ‑2 V / +2 V |
| Rated AC‑DC drainage current | 50 A |
| Impulse conduction voltage | ≤ 2200 V |
| Nominal discharge current In (8/20 μs waveform) | 100 kA |
| Maximum discharge current Imax (8/20 μs waveform) | 200 kA (Note: 50 kA for 10/350 μs waveform) |
| Leakage current | ≤ 10 μA |
| Fault current (30 cycles) | ≥ 3500 A |
| Response time | ≤ 1 ns |
| Operating temperature | ‑45 ℃ ~ 60 ℃ |
| Installation mode and location | Surface‑mounted on support / buried installation |
| Explosion‑proof classification | Explosion‑proof |
| Enclosure material | Stainless steel |
| Degree of enclosure protection | IP68 |
| Enclosure corrosion protection | Powder‑coated |
| Internal triple‑proof construction | Moisture‑proof, salt‑fog‑proof, bacteria‑proof |
| Internal high‑current connection cable | AGG‑10 kV silicone‑rubber high‑voltage cable |
3. Clamping‑Type Drainage Unit
| Parameter Item | Technical Specification |
|---|---|
| DC turn‑on voltage (at 1 mA) | ‑2 V / +2 V |
| Rated AC‑DC drainage current | 50 A |
| Impulse conduction voltage | ≤ 620 V |
| Nominal discharge current In (8/20 μs waveform) | 20 kA |
| Maximum discharge current Imax (8/20 μs waveform) | 40 kA |
| Leakage current | ≤ 20 μA |
| Fault current (30 cycles) | ≥ 3500 A |
| Response time | ≤ 25 ns |
| Operating temperature | ‑45 ℃ ~ 60 ℃ |
| Installation mode and location | Surface‑mounted on support / buried installation |
| Explosion‑proof classification | Explosion‑proof |
| Enclosure material | Stainless steel |
| Degree of enclosure protection | IP68 |
| Enclosure corrosion protection | Powder‑coated |
| Internal triple‑proof construction | Moisture‑proof, salt‑fog‑proof, bacteria‑proof |
| Internal high‑current connection cable | AGG‑10 kV silicone‑rubber high‑voltage cable |
Applicable Standard
Reference standard: GB/T 18802‑2021 Low‑voltage Surge Protective Devices (SPD)